Raritan PARAGON II Series Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach KVM-Schalter Raritan PARAGON II Series herunter. Raritan PARAGON II Series Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 117
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen

Inhaltsverzeichnis

Seite 2

2 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Paragon System Components Paragon consists of three components: the Paragon Matrix Switchi

Seite 3

92 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE SYMPTOM: PROBABLE CAUSE: Mouse suddenly locks up when a particular computer is selected,

Seite 4

CHAPTER 10: TROUBLESHOOTING 93 UTP Cabling FAQs Cat5 / Cat5e / Cat6 Cabling FAQs: QUESTION: ANSWER: What UTP cable does Raritan recommend for use w

Seite 5 - JAPANESE APPROVALS

94 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE QUESTION: ANSWER: Can I use non-certified Cat 5e cable? Yes, however, you may not get th

Seite 6

CHAPTER 10: TROUBLESHOOTING 95 QUESTION: ANSWER: Cat 5e is standardized. Why can’t I simply use any Cat 5e cable with Raritan products? Because the

Seite 7 - TABLE OF CONTENTS

96 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE QUESTION: ANSWER: Are there special pin out requirements that I must use? Yes, please r

Seite 8 - TABLE OF CONTENTS

CHAPTER 11: GLOSSARY 97 CHAPTER 11: GLOSSARY TERM: DEFINITION: Active Channel A channel is active when a connected device is powered on. See al

Seite 9 - CHAPTER 1: INTRODUCTION

98 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE TERM: DEFINITION: Global Scan Rate Scan rate used for all channels when Scan Mode field

Seite 10 - Paragon System Components

CHAPTER 11: GLOSSARY 99 TERM: DEFINITION: PowerSave Allows a properly equipped monitor to operate in energy save mode. See also Green Mode. Public

Seite 11

100 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE TERM: DEFINITION: Sort Order of channels listed in the Selection Menu – either by chann

Seite 12 - Paragon Cable Information

CHAPTER 11: GLOSSARY 101 TERM: DEFINITION: User Profile For setting and changing user passwords and preferences. UST1 Acronym for User Station X

Seite 13 - CHAPTER 1: INTRODUCTION 5

CHAPTER 1: INTRODUCTION 3 A complete Paragon setup may be configured as shown: Figure 4 Example of Basic Paragon Configurati

Seite 14

102 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE

Seite 15 - CHAPTER 2: INSTALLATION

APPENDICES 103 APPENDICES Appendix A: Paragon Update – Firmware Upgrade The Paragon Update Utility is a Win32-based program that facilitates the tr

Seite 16

104 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Paragon Configuration Backup: Paragon Update is designed to execute the firmware uploadi

Seite 17 - Configuration Options

APPENDICES 105 Update User Station(s) 1. On any active Paragon User Station (p/n UST1), log into Paragon, and press <F12> to display the Sele

Seite 18 - Menu Title

106 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Update Paragon Matrix Switching Unit(s) 1. Connect one end of a straight-through serial

Seite 19 - CHAPTER 2: INSTALLATION 11

APPENDICES 107 Appendix B: IBM x330 Paragon switch firmware versions 1P0 (UMT2161), 2C2 (UMT242, UMT442, and UMT8), or 3A2 (UMT1664) and User Stati

Seite 20 - Basic Installation

108 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Install an IBM x330 Rack of Servers as a Tier to Paragon: 1. Set up Paragon followin

Seite 22 - Figure 11 Login Menu

4 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Paragon Cable Information Paragon will work with any Category 5e UTP, Category 6 UTP, and

Seite 23 - CHAPTER 2: INSTALLATION 15

CHAPTER 1: INTRODUCTION 5 Category 5e Unshielded Twisted Pair (UTP) Cable Mod Plug Requirements for use with Raritan Category 5e UTP Products

Seite 24

6 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE

Seite 25 - CHAPTER 2: INSTALLATION 17

CHAPTER 2: INSTALLATION 7 CHAPTER 2: INSTALLATION Quick Start Important: All computers and Paragon components must be powered OFF prior to instal

Seite 26

8 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Administrative Setup: 1. At the Login Menu, displayed at the User Console attached to the

Seite 27 - Installing a Paragon Switch

CHAPTER 2: INSTALLATION 9 Administrator User Name and Password Defaults DEFAULT ADMINISTRATOR’S USER NAME: DEFAULT ADMINISTRATOR’S PASSWORD: admin

Seite 28

10 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Each OSUI menu contains the following sections: â Menu

Seite 29 - CHAPTER 2: INSTALLATION 21

CHAPTER 2: INSTALLATION 11 Function Keys: <F1>, <F2>, <F4>, and <F8> are used to switch among first-level menus. Pressing

Seite 30 - Back of UMT8

This page intentionally left blank

Seite 31 - HAPTER 2: INSTALLATION 23

12 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Basic Installation A predetermined number of users can access up to a certain number of c

Seite 32 - Front of UKVMSC

CHAPTER 2: INSTALLATION 13 Note: The Paragon Matrix Switching Unit’s Expansion Ports reserve a location for the future implementation of Raritan Ba

Seite 33 - CHAPTER 2: INSTALLATION 25

14 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE 3. Perform UST1 Administrative Setup. a. UST1 will establish communication with the Par

Seite 34 - Figure 21 Z-CIM UKVMSPD

CHAPTER 2: INSTALLATION 15 Note: If user console monitor displays a message “...No Connection to Paragon… ,” UST1 is not properly connected to the

Seite 35

16 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE 6. Perform Administrative Setup for CIMS and connected computers. The monitor connected

Seite 36 - as a Tier

CHAPTER 2: INSTALLATION 17 c. Use the <!> or <"> keys to highlight the Name field that corresponds with the Channel ID (Ch ID) whe

Seite 37 - CHAPTER 2: INSTALLATION 29

18 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Multi-Tier Installation Paragon’s channel capacity can easily be expanded with a tiered i

Seite 38

CHAPTER 2: INSTALLATION 19 Installing a Paragon Switch Follow the Basic Installation steps starting on page 12 to set up the base Paragon Switch, ma

Seite 39 - HAPTER 2: INSTALLATION 31

20 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Connecting Tiered Raritan KVM Switches to a Base Paragon Switch Connecting a Paragon Swit

Seite 40

CHAPTER 2: INSTALLATION 21 Guidelines for Paragon System Configuration 1. Only one user should attempt to modify/update the System Administration M

Seite 41 - HAPTER 2: INSTALLATION 33

Copyright © 2002 Raritan Computer, Inc. UMTx-0C-E September 2002 Raritan Computer Inc. 400 Cottontail Lane Somerset, NJ 0

Seite 42

22 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Connecting Z-Series Z4200U Z-CIMs as a Tier Important: Tiering a Z4200U chain requires

Seite 43 - CHAPTER 2: INSTALLATION 35

CHAPTER 2: INSTALLATION 23 Note: When following the installation and configuration instructions below, sort the Selection Menu by Channel ID Number

Seite 44

24 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE e. Optional: Connect a local user console to the UKVMSC Z-CIM. Figure 20 Connecting

Seite 45 - CHAPTER 2: INSTALLATION 37

CHAPTER 2: INSTALLATION 25 Name the Computer Channel on the Z4200U tiered Selection Menu: 1. When viewing the Paragon Selection Menu or any OSUI me

Seite 46

26 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Important: Repeat the steps on the previous pages: !Connect Z-Series Z4200U Z-CIMs as a T

Seite 47 - HAPTER 2: INSTALLATION 39

CHAPTER 2: INSTALLATION 27 6. Optional: Connect a local user console to the UKVMSC Z-CIM. Figure 23 Connecting a Local User Console to UKVMSC Z

Seite 48 - Installing a CIMPac

28 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Connecting a MasterConsole MX4 as a Tier Set MX4 User Port as a Second Tier Port: 1. Hol

Seite 49 - HAPTER 2: INSTALLATION 41

CHAPTER 2: INSTALLATION 29 12. Repeat these channel configuration steps for each path. You must name all MX4 paths with the same name. This will n

Seite 50

30 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Connecting a MasterConsole MXU2 as a Tier Figure 24 Connecting a MasterConsole MXU2 as a

Seite 51 - CHAPTER 2: INSTALLATION 43

CHAPTER 2: INSTALLATION 31 3. Set up the MXU2 as a second tier unit. a. At the Selection Menu, press <F5> to access the Administration Menu.

Seite 52

This page intentionally left blank

Seite 53

32 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE For MXU2 User 2 (Remote Category 5e UTP Port): a. Connect the other end of the Categor

Seite 54

CHAPTER 2: INSTALLATION 33 Connecting a MasterConsole II (Model MCC only) as a Tier Set MasterConsole II as a Tier Device: 1. When powering ON, pre

Seite 55 - HAPTER 3: OPERATING PARAGON

34 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Verify and Save Changes: 1. Press <F2> to go the Selection Menu to validate that th

Seite 56 - Selecting a Computer

CHAPTER 2: INSTALLATION 35 Connecting a MasterConsole P as a Tier Note: All tier MasterConsole P models must be MasterView ready. To determine w

Seite 57

36 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Verify and Save Changes: 1. Press <F2> to go to the Selection Menu to validate that

Seite 58 - OLOR: CHANNEL AVAILABILITY:

CHAPTER 2: INSTALLATION 37 Expanded Installation Options HubPac The Paragon HubPac, part number HUBPAC8-RK, expands user access capability to a maxi

Seite 59 - Public View Mode

38 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Important: Prior to installation, all Paragon switch units and HubPac units must be powe

Seite 60 - User Customization

CHAPTER 2: INSTALLATION 39 Perform Channel Configuration: Paragon recognizes a HubPac as an extension of a CIM, rather than as a device. As a resul

Seite 61

40 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE CIMPac The Paragon CIMPac, part number CIMPAC8-RK, expands user access capability to a ma

Seite 62

CHAPTER 2: INSTALLATION 41 Important: Prior to installation all Paragon Matrix Switch units and CIMPac units must be powered OFF. Computers and Us

Seite 63 - RESS: WHEN YOU WANT TO:

FCC INFORMATION FCC INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15

Seite 64 - A B D

42 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Perform Channel Configuration: Paragon recognizes a CIMPac as an extension of a CIM, rath

Seite 65 - N=Non-Active User # 1-8

CHAPTER 2: INSTALLATION 43 Rack Mount Brackets – RUMT and RUST Mounting brackets for Paragon components – Paragon Matrix Switch or User Station (UST

Seite 66

44 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Forward Mount Installation Figure 30 Forward Mount of Paragon Matrix Switch

Seite 67

CHAPTER 2: INSTALLATION 45 Reverse Mount Installation Figure 32 Reverse Mount of Paragon Matrix Switch – Rack p/n RUMT-1U Figure 33 Reverse

Seite 68 - RE-CONFIGURE

46 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE

Seite 69 - Figure 53 UST1 Direct Mode

CHAPTER 3: OPERATING PARAGON 47 CHAPTER 3: OPERATING PARAGON Login Login is required to access computers and devices connected to Paragon. The L

Seite 70

48 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE 3. The Selection Menu will appear. To navigate to other menus, use the function keys.

Seite 71 - Administration

CHAPTER 3: OPERATING PARAGON 49 Selection Menu by Name Page 1/4

Seite 72 - System Configuration

50 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Each channel’s availability is visually indicated on the Selection Menu by color: COLOR:

Seite 73 - OFF - JAYSON

CHAPTER 3: OPERATING PARAGON 51 Public View Mode OSUI Displays in Public View Mode Public View Mode enables viewing of another computer’s video, but

Seite 74 - User Configuration

This page intentionally left blank

Seite 75 - USER CONFIGURATION

52 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE User Customization The User Profile Menu displays Paragon configuration and allows for se

Seite 76 - Channel Configuration

CHAPTER 3: OPERATING PARAGON 53 Changing Passwords within User Profile Menu: 1. To add, delete, or change a password, press <P> while viewin

Seite 77 - CHANNEL CONFIGURATION

54 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE 8. Help: Set the help message at the bottom of each On-Screen User Interface (OSUI) menu

Seite 78 - User Station Profile

CHAPTER 3: OPERATING PARAGON 55 On-Screen User Interface (OSUI) Functions Use the following function keys to access Paragon OSUI functions: PRESS:

Seite 79 - Refresh Configurations

56 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Paragon Switch Front Panel Display and Controls The control buttons and LCD display on th

Seite 80

CHAPTER 3: OPERATING PARAGON 57 Normal Display: After start-up test, LCD panel displays two lines of messages: 1. Line 1: Running message: “Rarit

Seite 81 - Downloading Overview

58 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Function Selection Screen: Several administrative functions can be performed on the Funct

Seite 82 - Operating Overview Software

CHAPTER 3: OPERATING PARAGON 59 2. Display Ver./SN (Firmware Version and Serial Number): Displays current version of firmware and unit’s serial nu

Seite 83

60 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Note: Banking exemplifies Raritan’s dedication to future development. Banking Technolo

Seite 84 - Editing User Profiles

CHAPTER 4: USER STATION (UST1) DIRECT MODE 61 CHAPTER 4: USER STATION (UST1) DIRECT MODE User Stations (UST1s) set in Direct Mode can be connected

Seite 85 - Editing Device Profiles

TABLE OF CONTENTS I TABLE OF CONTENTS CHAPTER 1: INTRODUCTION 1 PARAGON FEATURES AND ADVANTAGES _____________________________________________ 1 PAR

Seite 86

62 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE CIM models capable of accepting a UST1 Direct Mode connection include: • UKVMC • UKVM

Seite 87 - Troubleshooting

CHAPTER 5: ADMINISTRATIVE FUNCTIONS 63 CHAPTER 5: ADMINISTRATIVE FUNCTIONS Administrative functions enable System Administrators to control the co

Seite 88

64 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE System Configuration The System Configuration Menu is used for setting global parameters.

Seite 89 - ETTINGS

CHAPTER 5: ADMINISTRATIVE FUNCTIONS 65 4. Operation Mode: There are three modes: Use <!> and <"> keys to select “Private,” “Public

Seite 90 - Recommendations

66 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE User Configuration The User Configuration Menu enables an administrator to add, delete, o

Seite 91 -

CHAPTER 5: ADMINISTRATIVE FUNCTIONS 67 Note: Press the <Tab> or the <#> key to move to the far right of the User Configuration Menu men

Seite 92

68 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Channel Configuration The Channel Configuration Menu enables an administrator to edit or

Seite 93 - CHAPTER 9: SPECIFICATIONS

CHAPTER 5: ADMINISTRATIVE FUNCTIONS 69 Note: Pressing the <Tab> or the <#> key to move to the far right of the Channel Configuration Me

Seite 94

70 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE User Station Profile The User Station Profile screen enables an administrator to select a

Seite 95 - HAPTER 9: SPECIFICATIONS 87

CHAPTER 5: ADMINISTRATIVE FUNCTIONS 71 Refresh Configurations Select item 5 - Refresh Configurations on the Administration Menu to refresh the datab

Seite 96

II TABLE OF CONTENTS USER STATION PROFILE_________________________________________________________ 70 REFRESH CONFIGURATIONS__________________________

Seite 97 - Connecting UTP Cables

72 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE

Seite 98

CHAPTER 6: OVERVIEW SOFTWARE 73 CHAPTER 6: OVERVIEW SOFTWARE Paragon Overview is a PC Windows-based program that provides an interface with Paragon

Seite 99 - CHAPTER 10: TROUBLESHOOTING

74 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Operating Overview Software Start Program: 1. Insert Overview software diskette into flo

Seite 100 - Multi-Tier Installation

CHAPTER 6: OVERVIEW SOFTWARE 75 Perform Administrator Login: This step requires administrator authorization to access UST1. 1. At the Login window,

Seite 101 - UTP Cabling FAQs

76 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Editing User Profiles Edit a User’s Profile: 1. Click User Profiles on left side of the

Seite 102 - UESTION: ANSWER:

CHAPTER 6: OVERVIEW SOFTWARE 77 Editing Device Profiles This feature is used to change computer names and profiles on a base Paragon, a tier Paragon

Seite 103

78 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE Uploading a Configuration File to Your System After any user profile, computer, and/or ot

Seite 104

CHAPTER 6: OVERVIEW SOFTWARE 79 Troubleshooting SYMPTOM: POSSIBLE CAUSE: Program begins. After clicking on the Activate Port button, a message ap

Seite 105 - CHAPTER 11: GLOSSARY

80 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE

Seite 106 - ERM: DEFINITION:

CHAPTER 7: PARAGON SECURITY: GROUP ID SETTINGS 81 CHAPTER 7: PARAGON SECURITY: GROUP ID SETTINGS The default group ID setting for all connected use

Seite 107 - CHAPTER 11: GLOSSARY 99

CHAPTER 1: INTRODUCTION 1 CHAPTER 1: INTRODUCTION Paragon Features and Advantages • 2U design supports 16 users, 64 computers (model UMT1664) • 1

Seite 108

82 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE GROUP ID FOR COMPUTERS: CAN BE ACCESSED BY USERS WITH GROUP IDs: 00 00 through 99 (al

Seite 109 - CHAPTER 11: GLOSSARY 101

CHAPTER 8: PERSONAL COMPUTER ACCESS VIA Z-CIM 83 CHAPTER 8: PERSONAL COMPUTER ACCESS VIA Z-CIM Paragon switch firmware versions 1P0 (UMT2161), 2C2

Seite 110

84 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE 3. Trace the Category 5e UTP cable from the chosen UST1 to the Paragon Switch and discon

Seite 111 - APPENDICES

CHAPTER 9: SPECIFICATIONS 85 CHAPTER 9: SPECIFICATIONS ITEM DIMENSIONS (WXDXH) WEIGHT POWER OPERATING TEMP. PARAGON SWITCH UMT2161 17.2” (W) X 1

Seite 112

86 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE ITEM DIMENSIONS (WXDXH) WEIGHT POWER OPERATING TEMP. CIMS FOR SUN USKVMC CONNECT ONE S

Seite 113 - Update User Station(s)

CHAPTER 9: SPECIFICATIONS 87 CIM Installation: Connecting CIM and Server CIM MODEL: CONNECTION INSTRUCTIONS: UKVMC • Connect DB25 male end of pr

Seite 114

88 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE CIM MODEL: CONNECTION INSTRUCTIONS: AUPUSBC • Connect DB25 male end of CCUSBnn cable to

Seite 115 - Appendix B: IBM x330

CHAPTER 9: SPECIFICATIONS 89 Connecting UTP Cables Recommended UTP cables: Category 5e UTP Cables: Belden DataTwist 350 UTP #1700A Solid Belden

Seite 116

90 PARAGON ADMINISTRATOR’S INSTALLATION AND OPERATION GUIDE CIM Cable Kits (For UKVMC): Additional cables available for desired distances longer tha

Seite 117 - 255-30-5004

CHAPTER 10: TROUBLESHOOTING 91 CHAPTER 10: TROUBLESHOOTING Symptoms and Solutions SYMPTOM: PROBABLE CAUSE: No Power. • Loose Power Cord. • Powe

Kommentare zu diesen Handbüchern

Keine Kommentare